aiptek - Aiptek USB Digital Tablet Input Driver for Linux
Section "InputDevice"
Identifier "idevname"
Driver "aiptek"
Option "Device" "devpath"
...
EndSection
aiptek is an XFree86 input driver for Aiptek HyperPen USB-based
tablet devices. This driver only supports the USB protocol, and only under
Linux; for RS-232C-based HyperPens, please see the hyperpen(4)
driver.
The
aiptek driver functions as a pointer input device, and may be used as the
X server's core pointer.
This driver supports the Aiptek
HyperPen 4000U, 5000U, 6000U, 8000U and 12000U USB-based input tablet on
some Linux platforms.
Please refer to XF86Config(5)
for general configuration details and for options that can be used with
all input drivers. This section only covers configuration details specific
to this driver.
Multiple instances of the Aiptek devices can cohabit. It
can be useful to define multiple devices with different active zones. Each
device supports the following entries:
- Option "Type" "stylus|eraser|cursor"
- sets the type of tool the device represent. This option is mandatory.
- Option
"Device" "path"
- sets the path to the special file which represents serial
line where the tablet is plugged. You have to specify it for each subsection
with the same value if you want to have multiple devices with the same
tablet. This option is mandatory.
- Option "USB" "on"
- specifies that you are
using the USB bus to communicate with your tablet. This setting is mandatory,
as USB is the only protocol supported by this driver.
- Option "DeviceName"
"name"
- sets the name of the X device.
- Option "Mode" "Relative|Absolute"
- sets
the mode of the device.
- Option "HistorySize" "number"
- sets the motion history
size. By default the value is zero.
- Option "AlwaysCore" "on"
- enables the
sharing of the core pointer. When this feature is enabled, the device will
take control of the core pointer (and thus will emit core events) and at
the same time will be able, when asked so, to report extended events. You
can use the last available integer feedback to control this feature. When
the value of the feedback is zero, the feature is disabled. The feature
is enabled for any other value.
- Option "XTop" "number"
- First of three sets
of parameters to set the active zone. This sets the X coordinate of the
top corner of the active zone. "TopX" is a synonym.
- Option "YTop" "number"
- First of three sets of parameters to set the active zone. This sets the
Y coordinate of the top corner of the active zone. "TopY" is a synonym.
- Option
"XBottom" "number"
- First of three sets of parameters to set the active
zone. This sets the X coordinate of the bottom corner of the active zone.
"BottomX" is a synonym.
- Option "YBottom" "number"
- First of three sets of
parameters to set the active zone. This sets the Y coordinate of the bottom
corner of the active zone. "BottomY" is a synonym.
- Option "XMax" "number"
- Second of three sets of parameters to set the active zone. This sets the
the X coordinate of the bottom corner of the active zone. The Top X corner's
coordinate is fixed at 0. "MaxX" is a synomyn.
- Option "YMax" "number"
- Second
of three sets of parameters to set the active zone. This sets the the Y
coordinate of the bottom corner of the active zone. The Top Y corner's coordinate
is fixed at 0. "MaxY" is a synomyn.
- Option "XOffset" "number"
- Third of three
sets of parameters to set the active zone. This sets the X coordinate of
the top corner of the active zone. "OffsetX" is a synomyn.
- Option "YOffset"
"number"
- Third of three sets of parameters to set the active zone. This
sets the Y coordinate of the top corner of the active zone. "OffsetY" is
a synomyn.
- Option "XSize" "number"
- Third of three sets of parameters to
set the active zone. This sets the X coordinate of the bottom corner of
the active zone. Unlike others, this parameter is expressed in relative
coordinates from the "XOffset" parameter. "SizeX" is a synomyn.
- Option "YSize"
"number"
- Third of three sets of parameters to set the active zone. This
sets the Y coordinate of the bottom corner of the active zone. Unlike others,
this parameter is expressed in relative coordinates from the "YOffset"
parameter. "SizeY" is a synomyn.
- Option "ZMin" "number"
- Minimum pressure
reading that will be accepted from the Stylus tool. "MinZ" is a synomyn.
- Option "ZMax" "number"
- Maximum pressure reading that will be accepted from
the Stylus tool. "MaxZ" is a synomyn.
- Option "XThreshold" "number"
- Minimal
change in X coordinate position that will be accepted as data input. "ThresholdX"
is a synomyn.
- Option "YThreshold" "number"
- Minimal change in Y coordinate
position that will be accepted as data input. "ThresholdY" is a synomyn.
- Option "ZThreshold" "number"
- Minimal change in pressure reading that will
be accepted as data input. "ThresholdZ" is a synomyn.
- Option "InvX" "on"
- Inverts X coordinate reports. "XInv" is a synomyn.
- Option "InvY" "on"
- Inverts
Y coordinate reports. "YInv" is a synomyn.
- Option "Pressure" "soft|hard|linear"
- Pressure reports either delivered in linearly incremental values (default),
or perturbed by one of two log-linear algorithms ("soft" or "hard").
- Option
"KeepShape" "on"
- When this option is enabled, the active zone begins according
to TopX and TopY. The bottom corner is adjusted to keep the ratio width/height
of the active zone the same as the screen while maximizing the area described
by the active area set of parameters, XTop/YTop/XBottom/YBottom, XMax/YMax,
or XOffset/YOffset/XSize/YSize.
- Option "DebugLevel" "number"
- sets the level
of debugging info reported.
This driver is currently Linux specific.
XFree86(1)
, XF86Config(5)
, xf86config(1)
, Xserver(1)
, X(7)
, hyperpen(4)
.
Bryan W. Headley <bheadley@earthlink.net>
http://aiptektablet.sourceforge.net
tracks ongoing development of this driver, the Linux kernel driver, and
a GUI front-end application that works in concert with the above.
Table of Contents